Loading Programs into Vulcan
-
Launch Praxis and Vulcan. Switch to Praxis and import Job spreadsheets from the C:\Program Files\Metamation\Praxis\Samples\Jobs folder. (Or load some parts and create new Job from the part library).
-
Select a job, right click, and use the Plan Job panel command. Select a bend machine.
-
Repeat Plan Job (previous step) and select Proteck Dual Head machine from the menu.
![Proteck Dualhead](img/proteck-vulcan.png)
Nests start appearing after a few seconds. Right click and use Send to Machineā¦ command to send the layouts to Vulcan.
![Send To Machine](img/send-to-machine.png)
Launch Vulcan and switch to Programs page. It lists programs to run in Proteck Dual Head queue. The program tiles display job details like sheets to run, estimated machine-time-per-sheet, Praxis raw-materials etc.
![Programs Page](img/programs-page.png)
The program list is updated as layouts are sent/recalled from Praxis. Programs are automatically refreshed when layouts are edited in Praxis.
Use the search box to search the programs by name, raw-material or LTT table. The examples below show results of programs searched by
-
Raw-material
-
LTT
![Layout](img/layout-ltt.png)
Removing programs from the queue
-
Switch to Praxis Job page or go to the nests tab.
-
Select one or more layouts, right click, and use the Recall from Machineā¦ panel command to remove the layouts from the production queue.
![Recall](img/recall-from-machine.png)
-
The Vulcan program list is automatically updated with the updated queue.